RTIndustry User Manual
RTIndustry monitors your computer numerical control (CNC) machine or your PLC in real time: it counts parts, measures times and calculates production efficiency. At the top of every screen you will find the ? Help button: it takes you straight to the explanation of that screen.
1First steps
What RTIndustry does and how to use it every day, in five minutes.
- The machine works, RTIndustry records. The software reads the machine state (running, paused, in alarm…), the part counter and, if an energy meter is installed, the consumption. You do not need to do anything: the data arrives by itself.
- Work is organized in work orders (WO). A work order is a job: what to produce and how many parts. You create it on the Work orders screen and start it by dragging it to "In progress". If the machine starts without an active work order, RTIndustry creates one by itself ("Job started by the machine") so that no parts are lost.
- The operator uses the HMI. The Machine HMI screen is designed for whoever is at the machine: parts made, scrap, status and big buttons.
- The supervisor checks the results. Telemetry, OEE, Reports, Energy and Alarms show how the shift is going and how past periods went.
How to open it
- Double-click the RTIndustry icon on the desktop, or
- right-click the RTIndustry icon next to the Windows clock → Open dashboard, or
- from another PC or tablet on the network: address
http://PC-NAME-OR-IP:1880.
Several machines on the same PC
Each RTIndustry installation follows one machine. To connect more machines from the same PC or server, you install several instances: run the installer again, choose Install a new instance and give it a name (for example Mill2).
- Each instance has its own folder (
C:\RTIndustry-Mill2), Windows service (RTIndustry-Mill2), icon, data, backups and license. - The installer suggests free ports: the first additional instance answers on
http://PC-NAME-OR-IP:1890, the second on:1900and so on (you can see them on the Advanced page of the installer). - The instance name appears at the top next to the logo, on the sign-in page and in the browser tab title.
- Each instance takes one seat of the license: with a multi-machine license you can use the same key in all of them.
- To update them, run the installer and choose which instance to update; uninstalling one instance does not affect the others.
2Sign in
Everyone signs in with their own username and password: every operation is recorded under their name.
- Enter your Username and Password.
- Press Sign in. The work orders screen opens, or the page you were trying to open.
To leave: menu with your name at the top right → Sign out.
There are two types of account:
| Role | What they can do |
|---|---|
| Operator | Work orders, HMI, telemetry, OEE, reports, energy, alarms, history. Cannot see Settings. |
| Administrator | Everything, plus Settings, license and Operators and activity log. The administrator account is created in the setup wizard. |
Changing your password: menu with your name at the top right → My password. Enter your current password, then the new one twice (at least 8 characters).
Too many failed attempts: after 5 wrong passwords in a row for the same username, sign-in from that device is blocked for 30 seconds; each further error doubles the wait, up to 15 minutes. Other users can keep signing in. The message on the page tells you how long to wait.
3Setup wizard
It appears only the first time, right after installation: in six steps the software is ready.
- Company — company name (required), plant, department, machine name and time zone (for Italy
Europe/Rome; daylight saving time is automatic). - Machine — choose the connection type: OPC UA, FANUC, Heidenhain, Modbus TCP or Simulator (test data, no machine). Enter the IP address and press Test the connection: the green "Machine connected" box confirms that state and parts are coming in. If the machine is off you can go ahead and try again later from Settings.
- Shifts — start and end times of each shift (night shifts too).
- License — enter the key (format
XXXX-XXXX-XXXX-XXXX) and press Activate license. Without a key a 30-day free trial starts. The box shows the result and the remaining days. If the company reaches the internet through a proxy, enter its address (and, if required, username and password) under Advanced options. - Administrator — username and password (at least 8 characters) of the first administrator.
- Start — check the summary and press Start RTIndustry.
5Work orders
The job board: what needs to be done, what is in progress, what is finished.
What you see
Three columns: To do, In progress, Completed. Each card shows code, description, program, parts made and, if set, the due date (in red if overdue). The card being worked on updates by itself while the machine produces.
Creating a work order
- Press + New work order.
- Fill in at least the Description. Useful: Requested quantity (for progress), Target time (s/part) (for performance), Due date, customer, order, part number, program, operator, notes.
- Press Save: the WO appears in "To do".
Starting, pausing, completing
- Drag the card to the column you want: in "In progress" it starts, in "Completed" it closes. On a tablet, press and hold the card for a moment before dragging it.
- The card in progress has quick buttons: Pause/Start, Scrap +1, Note, Complete.
- The icons on the card open the HMI of that WO, editing or deletion (with confirmation).
6Machine HMI
The operator's screen at the machine: large, readable, usable on a tablet even with gloves on.
What you see
- The work order in progress (or the one chosen from the list at the top), with due date, shift and machine status.
- The progress ring: good parts compared with the required parts.
- The cycle time deviation: how much the average part is slower (red) or faster (green) than the target time.
- Any active alarm, highlighted.
What you can do
- Scrap and Rework: with + and − you record the parts that are not good. Good parts are updated accordingly.
- Work order status: buttons Start, Pause, Stop, Set-up, Rework, Maintenance, Cleaning, Fault, Complete. Giving the reason for a stop makes the reports more accurate.
- Notes: write a note for the next shift and save it.
7Telemetry
How the current shift is going, updated every second.
- Parts / hour: production rate of the shift.
- Average cycle: running time divided by the parts produced.
- OEE: overall efficiency of the shift (see OEE).
- Shift energy: consumption since the start of the shift (if an energy meter is installed).
- Chart of the power over the last hour, breakdown of the shift's time by state and CNC details (program, feed rate, tool…).
8OEE
The international indicator of a machine's efficiency: 100% means always producing, at the expected speed, with no scrap.
OEE = Availability × Performance × Quality
| Factor | Question it answers | How to improve it |
|---|---|---|
| Availability | For how much of the shift did the machine work? | Reduce downtime, long set-ups, waiting. |
| Performance | Did it work at the expected speed? | Set a realistic target time in the WO; reduce micro-stops. |
| Quality | How many parts are good? | Record and reduce scrap and rework. |
The page shows the shift OEE (circular gauge), the three factors, the weekly trend (Monday → Sunday) and the breakdown by shift for the day.
9Reports
The analysis of a past period: a week, a month, a specific shift.
- Choose the period and, if you like, the shift in the filters at the top.
- Read the summaries: Average OEE, Good parts, Scrap, Energy.
- Below you find the OEE day by day, the time distribution (production, pause, idle, stopped, alarm, maintenance, set-up), energy compared with production and the list of completed work orders.
- With Export CSV you download the data for Excel.
10Energy
How much the machine consumes and how much each part costs. Available if an energy meter is connected.
- Real time: power drawn, shift energy, energy per part (Wh/part) and shift cost.
- Period history: total energy and cost, daily average, day-by-day consumption and the trend of Wh per part.
Connecting the energy meter
In Settings › Energy meter (Modbus) choose the meter model: the fields fill in by themselves and remain editable. For the IME CE4DT MID (Conto D4) the profile sets function FC4 (input register), unit ID 5, register 20592, type uint32, order ABCD and scale factor 100: you only need to enter the IP address. For other models choose Custom and copy register, data type and register order from the meter's manual.
The scale factor converts the value read into Wh (watt-hours), the unit RTIndustry uses for all its calculations: a meter that counts in kWh → factor 1000; in 0.1 kWh (like the IME) → 100; already in Wh → 1. Press Test reading: the result appears in Wh and in kWh and must match the total shown on the meter's display.
11Alarms
How long the machine has been in alarm and for what causes.
- Filters by period and shift.
- Summaries: time in alarm, days with alarms, percentage of machine time, daily average.
- Daily chart with the average line, breakdown by shift and event table: alarms longer than 5 minutes are highlighted.
- Export CSV for analysis in Excel.
12WO history
The complete archive of all work orders, including old ones.
- Search by code, description, customer, part number…
- Filter by status and sort by clicking a column header.
- Export CSV downloads exactly the list you are looking at.
13Settings
The whole configuration of the software, reserved for the administrator. Changes apply immediately, without restarting anything.
At the top you find the connection status with the machine (ONLINE in green) and the Test connection button. With Test the changes before saving you check a new address or protocol without touching the one in use.
| Section | What it is for |
|---|---|
| Machine and protocol | Connection type (OPC UA, FANUC, Heidenhain, Modbus, Simulator), IP address, security. When you change protocol, the previous configuration stays saved. |
| Machine variables | Where to read state, parts, program, alarms… from (usually suggested automatically by the profile). |
| State and mode mapping · part counter | How to translate the machine's values into RTIndustry states; how to count parts. |
| Energy meter (Modbus) | Connection to the energy meter (model, register, type and order, scale factor in Wh), with a test reading: see Connecting the energy meter. |
| Work shifts | Shift times. |
| Identity and access | Company and machine details. |
| Services, energy and license | Database and backup, energy price, time zone, license (activation and deactivation), Site Manager address and company proxy (if the PC reaches the internet through a proxy). |
| Work order integration (ERP, MES) | Receiving work orders from the management system. |
| Folders and transfers | Folders for attachments and programs; sending programs to Heidenhain controls. |
After making changes press Save: if you changed the machine connection, a connection test starts by itself.
How parts are counted
RTIndustry counts parts in one of these ways, chosen in Settings › State and mode mapping · part counter:
- Machine part counter (recommended): the software reads the control's counter (FANUC, SINUMERIK
actParts, OPC UA variable or Modbus register). - At program end (part counter calculated from the program): when the machine does not provide a part counter, each direct transition from Running to Program end counts as one part. It is the default mode for Heidenhain (program end recognized by
M30,M2/M02orEND PGM) and can be enabled on SINUMERIK with the acProg profile ifactPartsstays at 0. A reset after a stop (program aborted) does not count. - PLC counter (Heidenhain): if the NC program or the PLC keeps a counter, enter its path and the data access password; it works like the machine part counter.
SINUMERIK: the acProg (field-proven) profile uses the control's native nodes; the progStatus profile remains for controls that expose only that. With Detect the controller type the software suggests by itself the profile that responds.
Backup: every day RTIndustry saves a copy of the database in its own folder (last 7 days plus the last 4 Sundays). In Services, energy and license → Copy backups to another disk or network location you can set a second folder (for example D:\RTIndustry Backup or \\NAS\backup): this way, if the PC's disk fails, the history is not lost. Press Save, then Back up now: the message confirms whether the copy succeeded.
PC-NAME$) or the service must be installed with an account that has access to it. If in doubt, use a second disk or a USB stick that is always connected.14Operators and activity log
For the administrator only: personal operator accounts and the log of all operations (who did what and when).
Creating an operator account
- Menu + → Operators and activity log.
- Enter the Username (e.g. john.smith: letters, numbers, dot or hyphen), Full name and an Initial password of at least 8 characters.
- Press Create operator and give the password to the operator in person: they can change it from My password.
Managing accounts
| Button | Effect |
|---|---|
| Edit | Changes the full name or sets a new password (forgotten password). |
| Disable / Re-enable | Suspends access: the operator is signed out immediately, even if they had the page open. Their activities remain in the log. |
| Delete | Deletes the account. The activities remain in the log. For a temporary absence, Disable is better. |
Activity log
Lists, most recent first, every operation performed in the interface: sign-ins (including those rejected for a wrong password), sign-outs, creation, editing, moving, status changes, scrap and deletion of work orders, account management, saving of settings. For each one: date and time, user, activity, work order and details.
Filter by period (From / To), User and type of Activity, then press Filter. Export CSV downloads the filtered entries (up to 1000) to a file that opens in Excel.
15Machine and work order states
| State | Meaning |
|---|---|
| Running | The machine is producing. |
| Paused | Temporary pause. |
| Stopped · Fault | Machine stopped; fault if the cause is a malfunction. |
| In alarm | The control is signalling an alarm. |
| Idle · Program end | Switched on but not working; Program end when the program has reached its end (the time counts as idle). |
| Set-up · Rework | Preparing the machine; machining parts that must be redone. |
| Maintenance · Cleaning | Planned stops. |
| Completed | Work order closed. |
| Off or unreachable | No data from the machine for more than 15 seconds: switched off, cable disconnected or no network. |
16Using a tablet
From the menu with your name at the top right:
- Tablet mode (large buttons): bigger buttons, suitable for touch and gloves.
- Large text: characters easier to read from a distance.
- Keep screen on and Full screen, where the device allows it.
17Notification area icon
Next to the Windows clock there is the RTIndustry icon. Its color tells you at a glance whether everything is fine:
- Green — service running and license valid.
- Yellow — configuration to be completed or a warning (e.g. license about to expire).
- Red — service stopped or license not active.
With a right-click: installed version, service and license status, Open dashboard, Settings, Stop service/Restart service, Show log.
With several instances on the same PC there are several icons, one per instance: the instance name appears in the menu and in the tooltip when you hover over it (for example RTIndustry Mill2). The icon is also used to open the attachment and program folders from Settings: if it is closed, it reopens at the next Windows sign-in.
18License and messages
The license is verified over the internet with the Site Manager and is managed from Settings (administrator only). If the license is not active, operators see the Service suspended page and must contact the administrator.
If the connection is missing, RTIndustry keeps working normally and retries by itself: the license remains valid for a few days even without internet (temporary offline operation notice), then the connection is needed again.
Several machines
Each installation (instance) takes one license seat. With 8 machines you need 8 seats: usually a single key with 8 seats, entered in all the instances. The Site Manager shows how many seats are in use.
Moving the license to another PC
On the old PC: Settings › Services, energy and license › Deactivate this installation (frees the seat). On the new PC: install RTIndustry and enter the same key in the setup wizard. If the old PC no longer works, ask support to free the seat.
| Message | What to do |
|---|---|
| Trial period: N days remaining | Nothing. To continue after the trial, the administrator enters a key in Settings. |
| The license expires in N days | Contact your supplier to renew it. |
| Site Manager unreachable: temporary offline operation | Check the PC's internet connection. If the company uses a proxy, enter it in Settings › Services, energy and license. Work does not stop. |
| License expired: read-only interface | Data can be viewed but not changed. Renew within 30 days. |
| License seats used up | The key is already in use on another PC: deactivate it there (Settings › License) or request an additional seat. |
| Installation deactivated / No active license | Enter the key in Settings › Services, energy and license. |
| Inconsistent system clock | Correct the Windows date and time. |
19Requirements, network and antivirus
The RTIndustry PC
- Windows 10 (1809 or later) or Windows 11, 64-bit, 4 GB of RAM, 10 GB free; for several instances on the same PC allow about 100 MB of extra RAM for each machine (from 6 machines upwards 8 GB are recommended).
- Always on: sleep = Never (while the PC is asleep no data is collected); Windows updates outside working shifts.
- Correct date and time (shifts, reports and the license depend on the clock).
- Connected to the network of both the machines and the tablets or PCs used to view the dashboard; internet (HTTPS to
licenze.rtindustry.it) for the license.
Network ports
| Port | Use |
|---|---|
1880 | Dashboard (browser of tablets and PCs). Additional instances use 1890, 1900… (see Several machines on the same PC). |
1883 | MQTT for company systems (ERP, MES); additional instances 1893, 1903… |
| to the machines | FANUC 8193, OPC UA 4840, Heidenhain 19000, Modbus 502 (energy meter included). |
The installation opens these ports in the Windows firewall by itself.
Antivirus with its own firewall (Avast, AVG, Kaspersky, ESET, Bitdefender, Norton…)
Many paid antivirus programs (and their trial versions) replace the Windows firewall: the rules opened by the installation no longer apply and the tablets cannot reach the dashboard, even though it opens normally on the PC. Some of them wrongly flag the RTIndustryTray.exe icon as suspicious (a false positive: it is a new program not yet known to the antivirus).
In the antivirus settings:
- Exceptions / exclusions: add the
C:\RTIndustryfolder (and theC:\RTIndustry-…folder of each instance). - Firewall: allow incoming connections to the program
C:\RTIndustry\node\node.exe(one per instance), or set the shop-floor network as private/trusted. - If the icon has been quarantined, restore it from the antivirus quarantine and restart the PC.
http://PC-NAME-OR-IP:1880. The C:\RTIndustry\strumenti\Verifica-RTIndustry.bat tool reports whether a third-party firewall is present on the PC.20Troubleshooting
The machine shows "Off or unreachable"
- Check that the machine is switched on and the network cable is connected.
- In Settings press Test connection: the message tells you what is wrong (address, port, credentials).
The part count does not increase
- Check that there is a work order In progress and that the machine is Running.
- In Settings › State and mode mapping · part counter check the part counter variable.
- If the machine's part counter does not move (for example it stays at 0), enable counting at program end: see How parts are counted.
The page does not open
- Look at the notification area icon: if it is red, right-click → Restart service.
- From another PC: check that you are using the right address and port
1880(additional instances:1890,1900…).
The dashboard opens on the PC but not on the tablets
- It is almost always the antivirus firewall: see Antivirus with its own firewall.
- Check that the tablet and the PC are on the same network (or that the company network allows the connection).
The antivirus flags RTIndustry
- It is a false positive: add the exceptions described in Antivirus with its own firewall and restore the file from quarantine. Data collection (the service) continues even without the icon.
The "Short cycles" warning appears in Settings
- With counting at program end some parts may be missed because the cycle is shorter than three readings: use the machine part counter or a PLC counter (see How parts are counted).
Consumption looks 10, 100 or 1000 times wrong
- The energy meter scale factor is not right: the value must come out in Wh. See Connecting the energy meter and compare the reading with the meter's display.
Error codes
| Code | Meaning and solution |
|---|---|
RTI-E001 | The software does not start on this PC (folder copied from another PC, or PC name changed or Windows reinstalled). Reinstall RTIndustry: the data is kept. |
RTI-E011 | Port 1880 is taken by another program (for example the previous version). Close the other program or change the port. |
RTI-E020 / E021 | Database problem. Contact support: automatic daily backups exist. |
RTI-E030 | Installation identity cannot be read: the license must be reactivated. |
21Glossary
| WO (work order) | Production job: what to produce and in what quantity. |
| OEE | Overall Equipment Effectiveness, the overall efficiency of the machine. |
| HMI | Human Machine Interface, the operator's screen. |
| CNC | Computer numerical control of the machine tool. |
| PLC | Programmable logic controller. |
| Cycle time | Time to produce one part. |
| Target time | Expected cycle time, set in the work order. |
| Site Manager | The supplier's online service that manages licenses. |
| ERP / MES | Enterprise resource planning (company management system) / manufacturing execution system. |
| CSV | Data file that can be opened with Excel. |
| Instance | An RTIndustry installation dedicated to one machine; several instances can run side by side on one PC. |
| Part counter | Counter of the parts produced: the one in the machine's control, or calculated by RTIndustry at program end. |
| Energy meter | Electrical instrument that measures the machine's consumption, read via Modbus TCP. |
| Wh / kWh | Watt-hour / kilowatt-hour (1 kWh = 1000 Wh), units of the energy consumed. |
| Part program | Machining program run by the machine tool. |
22Support
For questions or problems contact the technician or reseller who installed RTIndustry, or write to assistenza@rtindustry.it.
When you ask for support, attach the diagnostics file: Settings › Export diagnostics button at the top. It contains version, software status and the latest operating messages, without passwords.
If the software does not open, attach instead the report of C:\RTIndustry\strumenti\Verifica-RTIndustry.bat (double-click it: it checks the PC, the network and the connection to the machine).